The TSIDCMRG Program Combining Multiple DSN Catalogs into a Single DSN Catalog (TSIDCMRG)
6-72 BIM-EPIC Installation and System Guide
the merged catalog backup has been restored, transfer the versions under the renamed dataset
name into the desired dataset name. When all the verisons have been transferred out of the
renamed dataset name, delete the renamed dataset name.
User defined datasets with names that are duplicated among the BIM-EPIC Catalogs and are
names involved with a multi-dataset group must be carefully reviewed. The best technique
for these situations would be to purge all the datasets involved in such a multi-dataset group
from all but one of the BIM-EPIC catalogs and, once the TSIDCMRG function has been
completed and the merged catalog backup has been restored, add each purged version.
The following is a typical example of SYSLOG activity when running the TSIDCMRG
program using the JCL as outlined above:
F4 0004 // JOB TSIDCMRG MERGE TWO CATALOGS INTO ONE
DATE mm/dd/yyyy, CLOCK hh/mm/ss
F4-0004 EP011 UNASSIGNED INPUT INPUT SYS004
4 580
F4-0004 EP800 IS THERE ANOTHER CATALOG BACKUP TAPE (Y|N)?
4 y
F4-0004 EP011 UNASSIGNED INPUT INPUT SYS004
4 580
F4-0004 EP800 IS THERE ANOTHER CATALOG BACKUP TAPE (Y|N)?
4 n
F4 0004 EP801 NO ERRORS DETECTED
F4 0004 EOJ TSIDCMRG MAX.RETURN CODE=0000
DATE mm/dd/yyyy, CLOCK hh/mm/ss, DURATION hh/mm/ss
Typical SYSLOG