
Recording Tape Cleaning
User Reference
Connectivity Systems, Inc.—Copyright © 2006
Use Pursuant to Company Instructions
2-51
Recording Tape Cleaning
Description You can record tape cleaning using either the Tape Volume Information
panel or the Manage Tape Volumes panel.
Procedure To access the Tape Volumes Information panel:
Manage Tape
Volumes Panel
The following is an example of the Manage Tape Volumes panel.
Procedure To record tape cleaning from either the Tape Volume Information panel
or the Manage Tape Volumes panel:
Using TSIDMNT
CLEAN
BIM-EPIC also provides TSIDMNT CLEAN to record tape cleaning. See
Chapter 3, “
TSIDMNT—DSN CATALOG MANAGEMENT
UTILITY,” for information on using CLEAN.
Step Action
1 Open the Primary Option menu.
2 Type M (Manage).
3 Press Enter to open the Search Catalog panel.
4 Tab to the Volser field.
5 Type the volume serial number in the Volser (Volume Serial
Number) field.
TSIO0400.r -------- BIM-EPIC - Manage Tape Volumes ------------- USER=SJA
COMMAND ===>
More: NO
Dataset: BILRECS BKUP TAPE Version: 5
Volser Reel Creation Expire --- Last Access --- Use Vault Slot
Date Date Date Job Count
_ 000143 1 03/28/1997 03/28/1997 03/28/1997 TVMBRRST 6 0 0
C = Clean I = Information M = Move P = Purge
F1=Help F3=Return F5=Recall F12=Exit
Step Action
1 Type C next to the volume serial number.
2 Press Enter to record tape cleaning.
Kommentare zu diesen Handbüchern