Memorex LOCK - VERSION 2-24 Technical Information Seite 437

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 568
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 436
Initializing Tapes for BIM-EPIC Control
User Reference
Connectivity Systems, Inc.—Copyright © 2006
Use Pursuant to Company Instructions
12-13
For non-virtual ACLs, a robot reads the cartridge barcodes. This
requires the volume serial numbers specified to TSIDINIT match
the appropriate barcodes.
Parameters PARM='CONSOLE' can be specified on the VSE EXEC statement to
allow the operator to control initialization from the console. This has the
same effect as entering EXEC TSIDINIT after a VSE // PAUSE’
statement.
PARM=’ACL=aclname[,COUNT=nnnnn]’
ACL= must precede COUNT=
Definitions The following provides definitions for the parameters you can use when
initializing tapes.
CUU Statement Under normal conditions, the operator is prompted to specify which tape
drives to use. Up to ten drives can be specified. However, if specific tape
drives should not be used, a cuu statement can eliminate operator
intervention.
If an ACL is used, operator intervention is not required. After a volume is
initialized, the volume is unloaded via a RUN command. After the RUN
completes, a robot “return to slot” action takes place. During this time,
another mount cannot take place until the return action is finished. It is
recommended that a minimum of two and no more than three drive
addresses (cuu) be used during a TSIDINIT execution.
The operator must verify that the ACL device addresses specified in the
cuu statements are not in use when TSIDINIT executes.
If the action takes place in a VM environment, the device addresses must
not be attached to a guest machine other than the machine in which
TSIDINIT executes. If unattached, TSIDINIT will attach the device
addresses when it begins execution and detach the devices when finished
executing.
Parameter Definition
aclname Designates the ACL to use for initialization. The
aclname must be same as the ACLNAME
parameter used in defining the cuu in the EPIC
Resource Dataset (ERD).
COUNT Designates the number of volumes to initialize. Use
COUNT only in sequential initializations. COUNT is
ignored if present for random initializations. A
maximum of 99,999 volumes can be initialized in a
TSIDINIT execution. When deciding the number of
volumes to initialize in one execution, consider the
time involved in robotic mount/demount activity.
Seitenansicht 436
1 2 ... 432 433 434 435 436 437 438 439 440 441 442 ... 567 568

Kommentare zu diesen Handbüchern

Keine Kommentare