Sorting Specifics
User Reference
Connectivity Systems, Inc.—Copyright © 2006
Use Pursuant to Company Instructions
7-41
Sorting Specifics
Many BIM-EPIC features rely on DTF information that is automatically
provided by the Logical Input Output Control Systems (LIOCS) access
methods. BIM-EPIC also relies on the standard open, close,
end-of-extent, and end-of-reel processing used by LIOCS. Not all sort
programs use LIOCS to process data so the functionality of the
BIM-EPIC features can vary depending on which sort product is used.
The following details how specific BIM-EPIC features perform when
used with several sort programs. These considerations apply when the
sort program is directly executed using the VSE EXEC statement and
then only to datasets that are opened directly by the sort program. These
considerations do not apply to datasets that may be opened by
user-written sort exits. The following characteristics apply to the
SORTWK file when the sort program is invoked by TSIDSRT or by
another program internally.
BIM-EPIC
feature
IBM SORT
prior to
DFSORT
3.3
IBM SORT
DFSORT 3.3 and
above
SYNCSORT
without interface
to BIM-EPIC
SYNCSORT
with interface
to BIM-EPIC
CA-SORT TSIDSRT
Reblocking No No No Yes No Ye s
Truncation of disk
output dataset
No No Yes Yes No Yes
Deletion of
SORTWK (using
close)
No Yes Yes Yes Yes Yes
DTF information
posting
No No No Yes No Yes
LUB allocation No Yes Ye s Yes Ye s Based on
sort
program
Disk dataset
concatenation
No Ye s No Yes Ye s Based on
sort
program
Tape dataset
concatenation
No Ye s Yes Yes No Based on
sort
program
Secondary
SORTWK
allocation
No Ye s Yes Yes Ye s Based on
sort
program
Assignments
required before
SORTIN,
SORTOUT or
SORTWK
opened?
Yes No No No No No