176 | Simrad MX500
Speed Over Ground Pulse Output
The MX500 can output the GPS calculated speed over
ground in a pulse format. Refer to the Specifications sec-
tion of this manual for signal characteristics.
The pulse output is derived from pins 7 (orange) & 8
(brown) of the AUX cable. The speed log out (+) is the
orange wire, while the speed log (-) is on the brown wire.
It is an RS-422 level signal, and may not be compatible
with every installation.
To setup the MX500 software, select the CFG1/Log Pulses
screen. This screen controls the output port (Pulse) of
the speed over ground log output from the MX500 at
a user determined pulse rate of 100 to 500 pulses per
nautical mile (200 is the pre-selected value). The default
condition of the Speed-Over-Ground output is “No” or not
active.
External Alarm Output
The MX500 Ext. alarm output connection is on pins 3 and
4 of the AUX (8-pin) cable. They are held open (float-
ing) during normal operations. In an alarm condition, the
external alarm pin is switched to ground potential. When
an alarm condition is cleared or acknowledged, the Ext.
alarm signal will return to open condition automatically
(refer to table below for relay conditions). However, it is
possible to retain the external alarm condition by setting
the “Retain external alarm:” to ON. At this setting, the
external alarm signal can only be cleared by correcting
the problem.